Ethernet UTP Cabling

UTP Cabling pinouts for 10BASE-T and 100BASE-TX

Two cooperating industry group, the Telecommunications Industry Association (TIA) and the Electronics Industry Alliance (EIA), define standards for UTP cabling, color coding for wires and standard pinouts on the cables.

.
EIA/TIA Standard Ethernet Cabling Pinouts


Note A UTP cable needs two pairs of wires for 10BASE-T and 100BASE-TX and four pairs of wires for 1000BASE-T.


To build a working Ethernet LAN, you must choose or build cables that use the correct wiring pinout on each end of the cable. 10BASE-T and 100BASE-TX Ethernet define that one pair should be used to send data in one direction, with the other pair used to send data in the other direction. In particular, Ethernet NICs should send data using the pair connected to pins 1 and 2—in other words, pair 3 according to the T568A pinout standard. Similarly, Ethernet NICs should expect to receive data using the pair at pins 3 and 6—pair 2 according to the T568A standard. Knowing what the Ethernet NICs do, hubs and switches do the opposite—they receive on the pair at pins 1,2 (pair 3 per T568A), and they send on the pair at pins 3,6 (pair 2 per T568A).

 Local Cable End Remote Cable End
 1 1
 2 2
 3 3
 6 6


The network shown uses a straight-through cable. A straight-through cable is used when the devices on the ends of the cable use opposite pins when they transmit data. However, when connecting two devices that both use the same pins to transmit, the pinouts of the cable must be set up to swap the wire pair. A cable that swaps the wire pairs inside the cable is called a crossover cable. For example, many LANs inside an Enterprise network use multiple switches, with a UTP cable connecting the switches.

Because both switches send on the pair at pins 3,6, and receive on the pair at pins 1,2, the cable must swap or cross the pairs. The next figure shows several conceptual views of a crossover cable
.


 Local Cable End  Remote Cable End
 1 3
 2 6
 3 1
 6 2




 Devices that transmit on 1,2 and receive on 3,6 Devices that transmit on 1,2 and receive on 3,6
PC NICs Hubs
Routers Switches
Wireless Access Points (Ethernet Interfaces)
Networked printers


1000BASE-T Cabling

Gigabit Ethernet does have a concept of straight-through and crossover cables, with a minor difference in the crossover cables. The pinouts for a straight-through cable are the same—pin 1 to pin 1, pin 2 to pin 2, and so on. The crossover cable crosses the same two-wire pair as the crossover cable for the other types of Ethernet—the pair at pins 1,2 and 3,6—as well as crossing the two other pairs (the pair at pins 4,5 with the pair at pins 7,8).


If you have some experience with installing LANs, you might be thinking that you have used the wrong cable before (straight-through or crossover), but the cable worked. Cisco switches have a feature called auto-mdix that notices when the wrong cabling pinouts are used. This feature readjusts the switch’s logic and makes the cable work.

maandag 6 augustus 2012

Disable DNS Lookup on Cisco Routers and Switches

Problem
In privilege EXEC mode, if you type in something other than a Cisco IOS command, the router assumes that you typed a domain name and it tries to resolve what ever you type.

Although this feature is can be useful in some situations, for most of the time, this is a pain, especially if you do not have DNS server configured. The router becomes irresponsive for about 5-6 seconds trying to resolve the name.

The following is an example.

R4#wrong-command
Translating "wrong-command"...domain server (255.255.255.255)
 (255.255.255.255)
Translating "wrong-command"...domain server (255.255.255.255)
 
% Unknown command or computer name, or unable to find computer address
R4#


Solution

To disable domain look up type the commands as shown billow.

R4#conf t
Enter configuration commands, one per line.  End with CNTL/Z.
R4(config)#no ip domain-lookup
R4(config)#

Now the output is quick and router does not become irresponsive


R4#wrong-command
Translating "wrong-command"
 
Translating "wrong-command"
 
% Unknown command or computer name, or unable to find computer address
R4#